Body: | Brass with nickel plated |
Shutter: | PPO |
Springs: | Stainless steel |
Seals: | EPDM |
Temperature setting range: | 35-45 C |
Hot water inlet temperature range | Below 100 C |
Cold water inlet temperature range | 4-29 C |
Temperature stability: | +/-2 C |
Hydrostatic pressure | 10bar |
Max working pressure(dynamic): | 5bar |
Working pressure: | 0.03-1Mpa |
Ideal working pressure | 0.1-0.5Mpa |
Connections | 1/2", Inlets: M, Outlet: M |
Flow rate (1 kg pressure drop) | 11.67 L/min |
1. Technical Data
DN15
a. Working pressure: 0.03-1Mpa
b. Ideal working pressure0.1-0.5Mpa
c. Maximum working temperature99 C
d. Hot water inlet temperature range50-95 C
e. Cold water inlet temperature range5-29 C
f. Outlet Temperature range: 35-45 C
g. Adjustment Accuracy+/- 2 C
h. Flow rate(1 bar pressure drop): 0.7Cb.m./H (Same as 11.67L/Min)
i. Elbow outlet port
2. Materials of Construction
a. Valve bodyBrass with Ni-Plated
b. ShutterPPO
c. SpringStainless steel
d. O-ringEPDM
e. ConnectionInlets-M, Outlet-M
(mm)
A:94, B:80,C:G1/2", D:23.5,E:60,F:30.
3. Features:
a. Fail-safe on Hot or Cold Supply Failure
b. Delivers Stable Mixed Water Temperature
c. Extended Mix Temperature Range35-45 C
d. Idea for Domestic Water Application
e. Tamper-Proof Cap
4. What is the thermostatic mixing valve?
A Thermostatic Mixing Valve is a valve that blends hot water (stored at temperatures high enough to kill bacteria) with cold water to ensure constant, safe outlet temperatures preventing scalding.
They shut-off rapidly in the event of a hot or cold supply failure to prevent scalding or thermal shock.
TMVs accurately control water temperatures for bathing, showering and hand-washing. They maintain pre-set temperatures - even if water pressure varies when other appliances are used. TMVs can be fitted under baths and basins, be part of shower fittings, or as a feature of exposed hot and cold water mixers.
5. Usage of TMVs
Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.
6. Installation Precaution:
a.All installations should be carried out by a Licensed Professional.
b.Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C.
c.After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2 C
d.The external check valves